Emily Walker Emily Walker
0 Course Enrolled • 0 Course CompletedBiography
Fire-Inspector-II Valid Test Pass4sure | Valid Fire-Inspector-II Exam Pass4sure
With the rapid development of the economy, the demands of society on us are getting higher and higher. If you can have Fire-Inspector-II certification, then you will be more competitive in society. Our study materials will help you get the according certification you want to have. Believe me, after using our study materials, you will improve your work efficiency. You will get more opportunities than others, and your dreams may really come true in the near future. Fire-Inspector-II Test Guide will make you more prominent in the labor market than others, and more opportunities will take the initiative to find you.
International Code Council Fire-Inspector-II is a certification exam to test IT expertise and skills. If you find a job in the IT industry, many human resource managers in the interview will reference what International Code Council related certification you have. If you have International Code Council Fire-Inspector-II Certification, apparently, it can improve your competitiveness.
>> Fire-Inspector-II Valid Test Pass4sure <<
Valid International Code Council Fire-Inspector-II Exam Pass4sure, Detailed Fire-Inspector-II Study Plan
We have free demos of our Fire-Inspector-II study materials for your reference, as in the following, you can download which Fire-Inspector-II exam materials demo you like and make a choice. We have three versions of our Fire-Inspector-II exam guide, so we have according three versions of free demos. Therefore, if you really have some interests in our Fire-Inspector-II Study Materials, then trust our professionalism, we promise a full refund if you fail exam.
International Code Council 67 - Fire Inspector II Exam Sample Questions (Q76-Q81):
NEW QUESTION # 76
What is the occupant load of a 2,500 net square foot assembly occupancy using tables and chairs?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
Explanation:
Reference to Occupant Load Factor Calculations:
The International Fire Code (IFC 2021), Table 1004.5 provides occupant load factors for different types of occupancies.
For assembly occupancy with tables and chairs, the occupant load factor is 15 square feet per person (net area).
Calculation of Occupant Load:
Formula: Occupant Load=Net Square FootageOccupant Load Factor ext{Occupant Load} = rac{ ext{Net Square Footage}}{ ext{Occupant Load Factor}}Occupant Load=Occupant Load FactorNet Square Footage Given: 2,500 net square feet, with a load factor of 15 sq. ft. per person: 250015=166.67#167 occupantsrac
{2500}{15} = 166.67 approx 167 ext{ occupants}152500=166.67#167 occupants Clarification of Incorrect Answer Choices:
A: 167 # Correct
Matches the exact IFC Table 1004.5 calculation.
B: 227 # Incorrect
Would correspond to a lower load factor (about 11 sq. ft. per occupant), which is not the standard for tables and chairs.
C: 357 # Incorrect
Would correspond to a 7 sq. ft. per occupant factor, used for tighter seating arrangements (e.g., assembly without fixed seats).
D: 500 # Incorrect
Would correspond to a 5 sq. ft. per occupant factor, typically used for standing areas or dense seating arrangements.
Conclusion:
The correct and verified answer is A (167 occupants) based on IFC Table 1004.5, using the standard occupant load factor for assembly occupancies with tables and chairs.
NEW QUESTION # 77
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.
- A. 2,000
- B. 1,000
- C. 0
- D. 2,500
Answer: A
Explanation:
LP-Gas Storage Limits for Dealers in Non-Public Buildings
According to the International Fire Code (IFC) 2021, Section 6109.9, the maximum allowable quantity of LP- gas in containers stored by a dealer awaiting resale in a building that is not open to the public is 2,000 pounds of water capacity.
This limit is intended to reduce fire and explosion hazards in enclosed spaces while allowing reasonable storage for commercial purposes.
2. Understanding Water Capacity vs. Propane Weight
The water capacity of an LP-gas cylinder refers to the total weight of water the container can hold, not the actual propane content.
The propane content is typically about 42% of the water capacity (i.e., 2,000 lbs. of water capacity is approximately 840 lbs. of propane).
3. Verification of Other Options
Option A (735 lbs.) - Incorrect, as IFC allows a significantly higher storage limit for dealers in non-public buildings.
Option B (1,000 lbs.) - Incorrect, as the actual limit per IFC 6109.9 is 2,000 lbs.
Option D (2,500 lbs.) - Incorrect, as this exceeds the IFC's maximum allowable storage limit.
Reference Sources:
International Fire Code (IFC) 2021 - Section 6109.9 (LP-Gas Storage Limits in Buildings Not Open to the Public) NFPA 58: Liquefied Petroleum Gas Code (LP-Gas Storage and Handling Guidelines) ICC Fire Inspector II Study Guide (2021)
NEW QUESTION # 78
In a control area where flammable liquid storage containers are in piles, there shall be a minimum of __ in. of clearance between the top of the storage and the deflector or discharge orifices of a sprinkler system.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
Explanation:
Clearance Requirement for Sprinkler Systems Over Flammable Liquid Storage According to International Fire Code (IFC) 2021, Section 5004.6 and NFPA 30: Flammable and Combustible Liquids Code, Section 16.5.1, there must be a minimum of 18 inches of clearance between the top of flammable liquid storage and the deflector or discharge orifices of a sprinkler system.
This ensures unobstructed sprinkler discharge for effective fire suppression.
2. Why 18 Inches is the Correct Answer
The 18-inch clearance allows sprinklers to operate properly, ensuring water distribution is not blocked by stored materials.
NFPA 13 also mandates an 18-inch minimum clearance for standard storage applications with sprinklers.
3. Verification of Other Options
Option B (24 inches) - Incorrect, as the IFC and NFPA specify 18 inches as the minimum requirement.
Option C (30 inches) - Incorrect, as this exceeds the required minimum clearance.
Option D (36 inches) - Incorrect, as the IFC and NFPA do not require this much clearance.
Reference Sources:
International Fire Code (IFC) 2021 - Section 5004.6 (Sprinkler Clearance Over Flammable Liquid Storage) NFPA 30: Flammable and Combustible Liquids Code - Section 16.5.1 NFPA 13: Standard for the Installation of Sprinkler Systems - Minimum Clearance Requirements ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: A. 18 inches. #
NEW QUESTION # 79
Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
Explanation:
Reference to Liquid-Level Limit Control Requirements for Atmospheric Tanks:
According to The International Fire Code (IFC 2021), Section 5704.2.7.5, atmospheric tanks containing hazardous materials must be equipped with a liquid-level limit control if their capacity exceeds 500 gallons.
This requirement ensures that overfilling is prevented, reducing the risk of hazardous spills, leaks, and fire hazards.
Purpose of Liquid-Level Limit Controls:
These controls automatically shut off or alert operators when the liquid level reaches a predetermined limit.
They prevent tank overfill and reduce the risk of hazardous material release, which can cause fires, explosions, or environmental contamination.
Clarification of Incorrect Answer Choices:
A: 55 gallons # Incorrect
55-gallon drums are not subject to the same overfill protection requirements as large atmospheric tanks.
B: 100 gallons # Incorrect
Too low based on IFC 5704.2.7.5, which sets the requirement at 500 gallons.
C: 250 gallons # Incorrect
Some local regulations may require monitoring for tanks of this size, but IFC specifies 500 gallons as the mandatory threshold.
Conclusion:
The correct and verified answer is D (500 gallons) based on IFC 5704.2.7.5, ensuring proper overfill protection for atmospheric tanks containing hazardous materials.
NEW QUESTION # 80
When more than 500 chairs are used for an assembly event held in a gymnasium, they must be secured to the floor or:
- A. be fastened together in groups of not less than 10.
- B. be fastened together in groups of not less than 3.
- C. be spaced at least 6 in. apart.
- D. be fastened together in groups of not less than 6.
Answer: B
Explanation:
Seating Arrangements for Large Assembly Events
According to the International Fire Code (IFC) 2021, Section 1029.14, when more than 500 chairs are used for an assembly event held in a gymnasium (or similar venue), they must be either:
Secured to the floor OR
Fastened together in groups of at least three (3) chairs.
2. Why Groups of 3 is the Correct Answer
This requirement ensures organized seating, preventing chairs from shifting or obstructing aisles during emergencies.
Properly fastened chairs reduce the risk of crowd-related hazards, ensuring safe and efficient evacuation if needed.
3. Verification of Other Options
Option A (spaced at least 6 inches apart) - Incorrect, as the IFC requires chairs to be fastened together or secured when over 500 are used.
Option C (groups of not less than 6) - Incorrect, as the minimum required grouping is 3.
Option D (groups of not less than 10) - Incorrect, as the IFC does not mandate groups of 10.
Reference Sources:
International Fire Code (IFC) 2021 - Section 1029.14 (Seating and Fastening Requirements for Assembly Events) NFPA 101: Life Safety Code (Seating Arrangements in Assembly Occupancies) ICC Fire Inspector II Study Guide (2021)
NEW QUESTION # 81
......
Taking Fire-Inspector-II practice exams is also important because it helps you overcome your mistakes before the final attempt. When we talk about the 67 - Fire Inspector II Exam (Fire-Inspector-II) certification exam, the International Code Council Fire-Inspector-II practice test holds more scoring power because it is all about how you can improve your Fire-Inspector-II Exam Preparation. Actual4Cert offers desktop practice exam software and web-based Fire-Inspector-II practice tests. These Fire-Inspector-II practice exams help you know and remove mistakes.
Valid Fire-Inspector-II Exam Pass4sure: https://www.actual4cert.com/Fire-Inspector-II-real-questions.html
The aim of our website is that help our customers pass Fire-Inspector-II real exam in a smart and cost-effective way, However, if you choose right Fire-Inspector-II sure pass test, you will find Fire-Inspector-II torrent training is totally close to you in fact, International Code Council Fire-Inspector-II Valid Test Pass4sure While each of them still hopes to pass the exam and get the certification, The experts in our company are always keeping a close eye on even the slightest change on the Fire-Inspector-II exam questions in the field.
Be as choosy with contractors as you would Fire-Inspector-II be with permanent staff, Ernie was an online consulting service that demonstrated the depth of intellectual capital in the three Exam Fire-Inspector-II Tests operating arms of Ernst Young: consulting, tax, and general accounting practices.
Up-to-Date International Code Council Fire-Inspector-II Exam Questions For Best Result
The aim of our website is that help our customers pass Fire-Inspector-II Real Exam in a smart and cost-effective way, However, if you choose right Fire-Inspector-II sure pass test, you will find Fire-Inspector-II torrent training is totally close to you in fact.
While each of them still hopes to pass the exam and get the certification, The experts in our company are always keeping a close eye on even the slightest change on the Fire-Inspector-II exam questions in the field.
If you are a beginner in IT industry, getting the Fire-Inspector-II certification will be the highlight in your resume.
- Fire-Inspector-II Test Dates ▛ Fire-Inspector-II Test Dates 🚗 Fire-Inspector-II Exam Torrent 🧥 Search for ▷ Fire-Inspector-II ◁ and download it for free on ⏩ www.testsimulate.com ⏪ website 😹Valid Fire-Inspector-II Test Vce
- Free PDF Quiz International Code Council - Fire-Inspector-II - 67 - Fire Inspector II Exam –Valid Valid Test Pass4sure 👴 Search for “ Fire-Inspector-II ” on “ www.pdfvce.com ” immediately to obtain a free download 🕳Exam Cram Fire-Inspector-II Pdf
- 100% Pass International Code Council - Fire-Inspector-II –Reliable Valid Test Pass4sure 👴 Search for ▛ Fire-Inspector-II ▟ and download it for free on ⇛ www.itcerttest.com ⇚ website 🤫Fire-Inspector-II Exam Torrent
- Examinations Fire-Inspector-II Actual Questions 🚺 Fire-Inspector-II Free Practice Exams 🏧 Valid Fire-Inspector-II Test Vce 🕝 Open ▷ www.pdfvce.com ◁ enter ➤ Fire-Inspector-II ⮘ and obtain a free download 🦡Fire-Inspector-II Free Practice Exams
- Exam Fire-Inspector-II Dumps 🏣 Online Fire-Inspector-II Test 🦩 Latest Fire-Inspector-II Test Camp 🎻 Search for 「 Fire-Inspector-II 」 and download exam materials for free through ( www.pass4test.com ) 🏚Fire-Inspector-II Reliable Test Simulator
- Fire-Inspector-II Valid Exam Notes ⌨ Fire-Inspector-II Test Dates 🕑 Latest Fire-Inspector-II Cram Materials 😴 Go to website ➤ www.pdfvce.com ⮘ open and search for { Fire-Inspector-II } to download for free 🥠Online Fire-Inspector-II Test
- Fire-Inspector-II Exam Pattern 😉 Fire-Inspector-II Test Discount ⬛ Fire-Inspector-II Test Dates 🤾 Immediately open ▶ www.examcollectionpass.com ◀ and search for ( Fire-Inspector-II ) to obtain a free download 🏂Fire-Inspector-II Valid Exam Notes
- Reliable International Code Council Fire-Inspector-II Valid Test Pass4sure offer you accurate Valid Exam Pass4sure | 67 - Fire Inspector II Exam 🌕 Immediately open [ www.pdfvce.com ] and search for [ Fire-Inspector-II ] to obtain a free download 🐌Latest Fire-Inspector-II Cram Materials
- 100% Fire-Inspector-II Accuracy 🔋 Latest Fire-Inspector-II Exam Format 🏗 Fire-Inspector-II Exam Sample Questions 🛴 The page for free download of 「 Fire-Inspector-II 」 on “ www.passtestking.com ” will open immediately 🧧Fire-Inspector-II Exam Sample Questions
- Fire-Inspector-II Test Discount 🥠 Online Fire-Inspector-II Test 😩 Fire-Inspector-II Test Dates 🛵 Go to website 「 www.pdfvce.com 」 open and search for ▷ Fire-Inspector-II ◁ to download for free 🧵Exam Fire-Inspector-II Dumps
- Fire-Inspector-II Valid Exam Notes 🐚 Latest Fire-Inspector-II Cram Materials 🖍 Exam Cram Fire-Inspector-II Pdf 🏛 Enter ⇛ www.lead1pass.com ⇚ and search for ➠ Fire-Inspector-II 🠰 to download for free 📏Fire-Inspector-II Test Dates
- trialzone.characterzstore.com, www.maoyestudio.com, global.edu.bd, www.rcams.ca, daotao.wisebusiness.edu.vn, motionentrance.edu.np, global.edu.bd, lms.ait.edu.za, globalzimot.com, inspiredtraining.eu